DAYTON AC Motors

Includes NEMA Premium rated Dayton motors ideal for applications in conveyors, pumps, fans and compressors. Available in steel and cast-iron frames and different voltage specifications and rpm ratings

Filter

Dayton AC motors are used in industrial machinery, HVAC systems and commercial equipment. They are ideal for tasks requiring continuous and consistent operation. These general-purpose AC motors cater... Read More

DAYTON -

Replacement Motors

StyleModelPrice (inc. GST)
A3NLE1A$ 3964.15
B310367A$ 2167.28
B52R994A$ 702.28
B310366A$ 2005.77
C52R993A$ 901.88
B304303A$ 1972.71
DAYTON -

Motor with Bracket, 480vs

StyleModelPrice (inc. GST)
AHV390011002001GA$ 1168.11
BPSC127-625BA$ 272.76
BPSC127-425FA$ 322.24
DAYTON -

Carbonator Pump Motors

StyleModelFull Load AmpsHPOverall LengthPrice (inc. GST)
A484H34---A$ 466.07
B484H33---A$ 548.51
C484H30---A$ 436.19
D484H31---A$ 470.39
E484H29---A$ 294.04
F484H285.1-5/2.6-2.5A1/47 11/16"A$ 371.11
G484H327.7-7.6/3.9-3.9A1/28 11/16"A$ 482.20
DAYTON -

General Purpose Motors

StyleModelCapacitor RequiredEfficiency GroupFrameFrame MaterialFull Load AmpsGreen Certification or Other RecognitionHPHzPrice (inc. GST)
A5PHA7--56Rolled Steel10.1/5.1-3/460A$ 744.23
B5K618BE--56Rolled Steel7.2/5.0-1/2, 1/460A$ 757.60
C48ZJ88-NEMA Premium Efficient56HRolled Steel4.3/2.1-1.550/60A$ 830.80
D48ZJ90-NEMA Premium Efficient56HRolled Steel5.7/2.8-250/60A$ 783.57
E5PHC0--------A$ 927.85
F48ZK02--------A$ 611.44
G6XH72--------A$ 688.55
H53DD29--------A$ 1120.67
I2TJ12--184TSteel20.5-560A$ 2153.34
J5GD60--56CSteel11.0/5.4-5.5-3/460A$ 833.36
B5K596BE--56Rolled Steel8.0-1/260A$ 588.19
K5K968--213TSteel20.5-560A$ 3052.84
L6K338--56HSteel14.5/8.0-7.4-1.560A$ 1648.75
M5UKH0--215TSteel41.5-1060A$ 4650.14
N6K146--184TSteel19.8-560A$ 2847.41
O6XJ15--56Rolled Steel5.5/3.0-1/3, 1/1060A$ 726.92
P30PT39-Premium Efficient56CRolled Steel3.8/1.9Energy Aware1/360A$ 707.70
Q36VF15-Premium Efficient56CRolled Steel1.5-1.4/0.70NEMA Premium Rated1/260A$ 478.82
R48ZJ83-NEMA Premium Efficient56HRolled Steel3.6/1.8-150/60A$ 759.87
S48ZJ85-NEMA Premium Efficient56HRolled Steel3.5/1.8-150/60A$ 992.72
T48ZJ86-NEMA Premium Efficient56HRolled Steel3.9/1.9-1.550/60A$ 907.48
U53DD28--------A$ 1118.40
V48ZK01--------A$ 1871.76
W48ZJ84-NEMA Premium Efficient56HRolled Steel3.0/1.5-150/60A$ 945.57
X48ZJ89-NEMA Premium Efficient56HRolled Steel5.0/2.5-250/60A$ 1045.87
DAYTON -

DC Gearmotor Component Motors

StyleModelFull Load AmpsHPLength Less ShaftNameplate RPMNEMA/IEC FrameOverall LengthShaft Dia.Shaft LengthPrice (inc. GST)
A23L3780.51/304.75"3000805.25"5/16"9/16"A$ 306.14
B23L3870.71/194.125"3000904 13/16"3/8"3/4"A$ 371.18
C23L3771.71/304.75"2850805.25"5/16"9/16"A$ 306.34
D23L4055.61/85.625"2920906.437"7/16"13/16"A$ 443.15
E23L40410.51/85.625"2750906.437"7/16"13/16"A$ 496.40
DAYTON -

AC Gearmotor Component Motors

StyleModelFull Load AmpsHPLength Less ShaftMotor Thermal ProtectionNameplate RPMOverall LengthShaft Dia.Shaft LengthPrice (inc. GST)
A23L373--------A$ 751.91
B23L3890.681/124 29/32"Auto16005 11/16"7/16"13/16"A$ 558.94
C23L4081.41/46 13/32"None15507.437"1/2"1"A$ 795.91
D23L4072.851/46 13/32"None16007.437"1/2"1"A$ 864.06
DAYTON -

Open Drip Proof Motor 115V

StyleModelPrice (inc. GST)
A11J31R04094-002A$ 1198.70
B11J31R04090A$ 577.22
C11J31R04091A$ 842.51
B11J31R04766A$ 656.09
B11J31R08361-001A$ 767.22
DAYTON -

General Purpose Motors, Capacitor Start / Run, NEMA

Dayton capacitor start general purpose motors are designed to power commercial, industrial, centrifugal and hydraulic pumps, fans, blowers and conveyor equipment. These single phase 50 / 60HZ motors can produce a maximum output of 2HP and delivery speed of 3450 RPM. They feature NEMA rated frame with rolled steel construction and open dripproof enclosure for durability. The shaft can rotate in both clockwise and counterclockwise directions for better work feasibility. CSA-certified and UL-recognised for reliable operation. Choose from a wide range of these general purpose motors, available in power ratings of 1/4, 1/3, 1/2, 3/4, 1, 1.5 and 2 HP on Raptor Supplies.

StyleModelEfficiency GroupFrameFrame MaterialFull Load AmpsHPInsulation ClassLength Less ShaftMotor Mounting PositionPrice (inc. GST)
A20CL53Energy Efficient48Steel4.4/2.4-2.21/2B9"Horizontal or Vertical Shaft DownA$ 756.92
B30PT81NEMA Premium(R)56Rolled Steel13.4/6.71.5B11.375"HorizontalA$ 1329.29
C30PT91NEMA Premium(R)56Rolled Steel8.9/4.61F11.375"HorizontalA$ 1567.24
D30PT90NEMA Premium(R)56Rolled Steel7.0/3.63/4B9.875"HorizontalA$ 934.44
E30PT89NEMA Premium(R)56Rolled Steel7.0/3.63/4B9.875"HorizontalA$ 895.51
F30PT88NEMA Premium(R)56Rolled Steel13.3/6.71.5B10.875"HorizontalA$ 1002.32
G30PT85NEMA Premium(R)56Rolled Steel17.3/8.72B12.375"HorizontalA$ 1281.53
H30PT84NEMA Premium(R)56HRolled Steel17.3/8.72B12.375"HorizontalA$ 1234.84
I30PT69NEMA Premium(R)56Rolled Steel7.0/3.53/4B10.375"HorizontalA$ 851.55
J31TR70NEMA Premium(R)56HRolled Steel17.6/9.5-8.82B11.25"All AngleA$ 1689.95
K30PT79NEMA Premium(R)56Rolled Steel8.9/4.61B10.375"HorizontalA$ 1642.94
L30PT78NEMA Premium(R)56HRolled Steel8.8/4.41B10.375"HorizontalA$ 1187.51
M30PT77NEMA Premium(R)56Rolled Steel8.8/4.41B10.375"HorizontalA$ 963.68
N30PT76NEMA Premium(R)56Rolled Steel8.8/4.41B10.375"HorizontalA$ 894.96
O30PT75NEMA Premium(R)56Rolled Steel9.3/4.31B11.375HorizontalA$ 992.76
P30PT74NEMA Premium(R)56Rolled Steel9.3/4.31B11.375"HorizontalA$ 1021.64
Q30PT68NEMA Premium(R)56Rolled Steel4.8/2.41/2B10.375"HorizontalA$ 1243.44
R30PT80NEMA Premium(R)56Rolled Steel13.3/6.71.5B10.875"HorizontalA$ 1137.53
S31TR71NEMA Premium(R)56Rolled Steel17.6/9.5-8.82B11.25"All AngleA$ 1713.91
T30PT66NEMA Premium(R)56HRolled Steel6.4/3.21/2B9.375"HorizontalA$ 1051.33
U31TR87NEMA Premium(R)56HRolled Steel8.4/4.6-4.21B10 11/16"All AngleA$ 1477.99
V31TT03NEMA Premium(R)56Rolled Steel8.8/4.9-4.41B10.437"HorizontalA$ 956.42
J31TR98NEMA Premium(R)56HRolled Steel13.2/7.0-6.61.5B11"HorizontalA$ 1351.60
W31TR96NEMA Premium(R)56Rolled Steel5.6/3.0-2.81/2B9 11/16"All AngleA$ 1247.98
S31TR95NEMA Premium(R)56Rolled Steel3.4/1.8-1.71/3B10"All AngleA$ 1005.23
DAYTON -

General Purpose AC Motors, 3 Phase Design, Keyed Shaft

Dayton three-phase general purpose motors are ideal for high torque applications, such as compressors, fans, conveyors, pumps, material handling and machine tools. These units feature rolled steel frames for durability and structural rigidity and have ball bearings for a smooth and continuous operation. They have open drip-proof or totally enclosed fan cooled enclosures for keeping the internal components safe from overheating and moisture. Choose from an extensive range of these class F insulated motors, available in power outputs ranging between 1 and 3 hp.

StyleModelFull Load AmpsHPLength Less ShaftMotor Enclosure DesignNameplate RPMNominal EfficiencyOverall LengthRPM GroupPrice (inc. GST)
A31TU312.9-2.7/1.4110.75"Totally Enclosed Fan-Cooled345081.5%13.125"3001-3600A$ 797.55
B31TU223.0-2.9/1.5110.75"Open Dripproof345080.0%13.25"3001-3600A$ 707.87
A31TU323.1-3.0/1.5110.75"Totally Enclosed Fan-Cooled175085.5%13.125"1701-1800A$ 853.76
C31TU233.2-3.1/1.6110.25"Open Dripproof175085.5%13.25"1701-1800A$ 1423.82
A31TU333.6-3.5/1.8110.75"Totally Enclosed Fan-Cooled115082.5%13.125"1101-1200A$ 1083.83
D31TU244.0-4.0/2.0112 1/16"Open Dripproof115082.5%13.25"1101-1200A$ 1133.64
E31TU365.4-4.9/2.5210.75"Totally Enclosed Fan-Cooled350585.5%13.125"3001-3600A$ 976.57
F31TU275.5-5.0/2.5210.25"Open Dripproof348085.5%13.25"3001-3600A$ 891.56
G31TU285.9-5.0/2.5210.25"Open Dripproof174086.5%13.25"1701-1800A$ 872.55
H31TU375.9-5.7/2.8210.75"Totally Enclosed Fan-Cooled174086.5%13.125"1701-1800A$ 1044.34
I31TU388.1-7.2/3.6310.75"Totally Enclosed Fan-Cooled348086.5%13.125"3001-3600A$ 1113.75
G31TU298.2-7.3/3.7310.25"Open Dripproof348085.5%13.25"3001-3600A$ 959.59
J31TU308.2-7.6/3.8313.875"Open Dripproof174089.5%15.25"1701-1800A$ 1149.28
DAYTON -

General Purpose Motors, 1/2 Hp Power Output, ODP Enclosure

Dayton general purpose motors are used with compressors, fans, conveyors, pumps, material handling and machine tools. These units feature open drip-proof (ODP) enclosures that have ventilated openings to allow inflow directly over the motor windings to dissipate heat due to continuous operation. They include shaft slingers for sealing shaft bearings against dust and other contaminants while retaining lubrication. These motors have steel construction with 3-phase motor design to operate with higher torque and greater efficiency as compared to single-phase models having the same power outputs (hp), speeds (rpm) and frame sizes. Choose from a wide range of these general-purpose AC motors, available in horizontal & all angle mounting positions.

StyleModelFull Load AmpsLength Less ShaftMotor Enclosure DesignNameplate RPMNominal EfficiencyOverall LengthRPM GroupRPM RangePrice (inc. GST)
A31TU254.2-3.8/1.910.25"Open Dripproof345085.5%13.25"3001-36003001-3600A$ 848.65
B31TU344.2-3.9/1.910.75"Totally Enclosed Fan-Cooled351084.0%13.125"3001-36003001-3600A$ 950.97
C31TU264.4-4.2/2.110.25"Open Dripproof174086.5%13.25"1701-18001701-1800A$ 925.56
D31TU354.5-4.3/2.110.75"Totally Enclosed Fan-Cooled174086.5%13.125"1701-18001701-1800A$ 976.57
DAYTON -

Motor 3-phase 2 Hp

Dayton general purpose motors are used in fans, compressors, conveyors, pumps, material handling and machine tools. These motors have three windings to generate a magnetic field inside the frame of the motor and are ideal for use in non hazardous applications. They feature NEMA frame construction with standard dimensions that permit drop-in replacement of motors from different suppliers without the need of any modifications to existing installations. Choose from a range of these motors, available in motor speeds of 1725 and 3450 RPM on Raptor Supplies.

StyleModelFull Load AmpsLength Less ShaftNameplate RPMNominal EfficiencyOverall LengthRPM GroupRPM RangePrice (inc. GST)
A31TT075.5-5.4/2.710.75"345085.5%12 11/16"3001-36003001-3600-
RFQ
B31TT226.2-6.0/3.011 7/32"172586.5%13.437"1701-18001701-1800A$ 1119.87
DAYTON -

Three Phase Motors, 1-1/2 HP Power Output, Steel Frame

Dayton general purpose AC motors are designed to operate in high torque applications, ideal for non-hazardous applications, such as compressors, fans, conveyors, pumps, material handling and machine tools. Unlike single-phase models, these units do not require start / run capacitors or centrifugal switches that may fail or wear, causing issues like motor shutdown, overheating and vibrations. They have rolled steel frames for durability and ball bearings for a smooth and continuous operation. Choose from a wide range of these three-phase motors, available in open drip-proof and totally enclosed fan cooled enclosures.

StyleModelFull Load AmpsLength Less ShaftMotor Mounting PositionNameplate RPMNominal EfficiencyOverall LengthRPM GroupRPM RangePrice (inc. GST)
A31TT081.7-1.7/0.859.125"All Angle172578.2%11 3/32"1701-18001701-1800A$ 1004.08
B31TT112.6-2.8/1.49.75"Horizontal114075.3%11 23/32"1101-12001101-1200A$ 1158.63
DAYTON -

Motor 3-phase

Dayton 3-phase general purpose AC motors are ideal for use in pumps, ventilation equipment, machine tools and other industrial equipment to eliminate the need for capacitor start motors. These 3-phase motors feature three windings for creating a naturally rotating magnetic field to rotate the shaft and NEMA-rated construction in rolled steel frame for durability. They have Class B insulation rating for safe use and are equipped with ball bearings for smooth operation. The motor can produce a max output of 1.5 HP and max speed of 3600 RPM. Choose from a wide range of 3-phase motors, available in 50 na d 50H frame variants on Raptor Supplies.

StyleModelCapacitor RequiredFrameFull Load AmpsHPInverter RatedLength Less ShaftMotor Mounting PositionNameplate RPMPrice (inc. GST)
A31TT10No561.3-1.4/0.701/3Yes10"Horizontal1140-
RFQ
B31TT12No563.0-3.0/1.51Yes9.75"All Angle1725A$ 1281.87
C31TT14No562.6-2.5/1.33/4Yes9.375"All Angle1725A$ 868.76
D31TT16No56H3.2-3.5/1.83/4Yes12 1/16"All Angle1140A$ 1406.79
E30PT92Yes563.0-3.0/1.51No8.25"Horizontal3450A$ 671.09
F30PT93Yes564.3-4.2/2.11.5No9.25"Horizontal3450A$ 1033.98
DAYTON -

Motors

StyleModelFits BrandFor Use With Grainger Item NumberFor Use With Mfr. Model NumberItemPrice (inc. GST)
A1VLC5---MotorA$ 1272.73
BPP2LTAF21TBG---MotorA$ 2027.72
CPP2LTAB23SCG---MotorA$ 766.54
DPP2LTAC21SBG---MotorA$ 1239.51
EPP2LTAC23SCG---MotorA$ 836.27
FPP2LTAC23TCG---MotorA$ 929.24
GPP2LTAD21SBG---MotorA$ 1295.46
FPP2LTAD21TBG---MotorA$ 1374.34
HPP2LTAD23SCG---MotorA$ 899.89
FPP2LTAD23TCG---MotorA$ 963.19
IPP2LTAE21SBG---MotorA$ 1171.28
JPP2LTAE23SCG---MotorA$ 1184.97
KPP2LTAE23TCG---MotorA$ 1137.84
LPP2LTAF23TCG---MotorA$ 1610.79
MPP2LTAA21SBG---MotorA$ 744.01
NPP2LTAG21TBG---MotorA$ 2257.79
OPP2LTAG23TCG---MotorA$ 1740.14
FPPLTAF21TAG---MotorA$ 1604.57
FPPLTAG21TEG---MotorA$ 1569.22
PHV1633300G---MotorA$ 717.45
FP151-D02-1009---MotorA$ 1048.22
FP150-541-1003---MotorA$ 1475.68
Q50B899---MotorA$ 787.97
F502113510005---MotorA$ 1990.99
R31UK96---MotorA$ 21.47
DAYTON -

General Purpose Split Phase Motors, TEFC, 1725 RPM, 48Z

Dayton general purpose split-phase motors are designed for low-to-medium-torque applications, such as for blowers, fans and small conveyors where gradual speed build up is required. Their totally enclosed fan-cooled enclosure in rolled steel NEMA frame features a continuous duty motor with multiple speed settings for desired operation. The Class F insulation ensures operation in high temperature environment. They are equipped with ball bearings for smooth delivery while shaft can rotate in both clockwise and counter clockwise direction. Choose from a wide range of split phase motors, available in 3.2, 4.7 and 4.9 ampere current ratings on Raptor Supplies.

StyleModelFull Load AmpsHPLength Less ShaftMountingNameplate RPMNumber of SpeedsOverall LengthShaft LengthPrice (inc. GST)
A6XJ06BE3.21/69 2/16"Base1725111"1.875"A$ 405.66
B6XJ054.7/3.31/4, 1/12-Cradle Base1725/1140211.437"1.5"A$ 628.57
A6XJ07BE4.91/48 11/16"Base1725110.625"1.875"A$ 423.91
DAYTON -

General Purpose Motors, Split Phase, TEFC

Dayton split-phase general purpose motors are designed to power blowers, fans and small conveyors. These motors have both main and auxiliary windings to provide both clockwise and counterclockwise rotations. The motors are enclosed in a steel constructed NEMA rated frame for protection and easy replacement. The keyed shaft makes rotation easier and decreases the chances of an error. Choose from a wide range of these TEFC motors, available in 1/8, 1/4, 1/3 and 1/2 HP power ratings on Raptor Supplies.

StyleModelFrameFull Load AmpsHPInsulation ClassLength Less ShaftMotor Shaft DesignNameplate RPMNumber of SpeedsPrice (inc. GST)
A6XJ0148Z3.51/8B9.187"Flat11401A$ 560.13
B6XJ10BE565.91/3B9"Keyed17251A$ 508.37
B6XJ11BE568.01/2F9 8/16"Keyed17251A$ 588.19
B6XJ58BE567.2/5/01/2, 1/4B10 14/16"Keyed1725/11402A$ 1111.58
DAYTON -

General Purpose Motor Carbon Steel Tefc

StyleModelFrameFull Load AmpsHPInsulation ClassLength Less ShaftMotor Thermal ProtectionMountingNameplate RPMPrice (inc. GST)
A5UKF4489.4/5.0-4.73/4B10.5"NoneBase3450A$ 829.57
B1K08056C10.6/5.3-5.33/4B10 4/16"AutoFace/Base3450A$ 917.92
C1K08156C10.0/5.4-5.13/4B9 13/16"NoneFace/Base1745A$ 1106.67
D6K83156C10.6/5.3-5.33/4B10 1/16"AutoFace3450A$ 625.52
E6K83256C14.2/7.7-7.11.5B10 11/16"AutoFace3450A$ 826.24
F5UKG456H18.0/10.0-9.02B11.75"NoneBase3450A$ 1141.44
G6XJ5356H14.2/7.7-7.11.5B11"AutoBase3450A$ 1156.85
H5UKG8145T13.03F12"NoneBase3500A$ 1791.13
I6K179213T32.07.5F16.5"NoneBase3450A$ 3961.76
J6K176215T32.07.5F16 12/16"NoneBase1725A$ 3718.61
DAYTON -

General Purpose Motor Capacitor Start/run Open Dripproof

StyleModelEfficiency GroupFrameFrame MaterialFull Load AmpsHPLength Less ShaftMotor Shaft DesignMotor Thermal ProtectionPrice (inc. GST)
A20CL54Energy Efficient48Steel4.4/2.4-2.21/29"FlatNoneA$ 710.82
A20CL60Energy Efficient48Steel4.6/2.4-2.31/29.5"FlatNoneA$ 1025.86
A20CL55Energy Efficient48Steel7.2/4.0-3.63/49.5"FlatNoneA$ 813.49
A20CL63Energy Efficient48Steel2.4/1.2-1.21/48.75"FlatAutoA$ 793.43
A20CL56Energy Efficient48Steel4.6/2.4-2.31/29.5"FlatAutoA$ 828.02
A20CL57Energy Efficient48Steel3.0/1.6-1.51/38.5"FlatAutoA$ 785.51
A20CL64Energy Efficient48Steel3.8/1.9-1.91/39"FlatAutoA$ 839.23
A20CL62Energy Efficient48Steel4.4/2.4-2.21/29"FlatManualA$ 839.40
A20CL61Energy Efficient48Steel3.8/1.9-1.91/39"FlatNoneA$ 900.53
A20CL59Energy Efficient48Steel7.2/4.0-3.63/49.5"FlatAutoA$ 848.98
B20VD15NEMA Premium(R)56Rolled Steel7.4/4.0-3.63/49.5"KeyedAutoA$ 823.02
C20VD14NEMA Premium(R)56CRolled Steel2.4/1.2-1.21/48.625"KeyedAutoA$ 936.12
B20VD09NEMA Premium(R)56Rolled Steel3.8/1.9-1.91/39"KeyedManualA$ 868.93
B20VD07NEMA Premium(R)56Rolled Steel3.8/1.9-1.91/39"KeyedAutoA$ 837.25
B20VD06NEMA Premium(R)56Rolled Steel4.6/2.4-2.31/29.5"KeyedNoneA$ 873.61
B20VD04NEMA Premium(R)56Rolled Steel2.4/1.2-1.21/48.75"KeyedAutoA$ 915.10
C20VD12NEMA Premium(R)56CRolled Steel3.8/1.9-1.91/38.875"KeyedAutoA$ 872.86
B20VD19NEMA Premium(R)56Rolled Steel4.4/2.4-2.21/29"KeyedNoneA$ 783.22
B20VD20NEMA Premium(R)56Rolled Steel6.6/3.6-3.33/49.5"KeyedNoneA$ 836.49
B20VD18NEMA Premium(R)56Rolled Steel4.4/2.4-2.21/29"KeyedManualA$ 770.59
B20VD16NEMA Premium(R)56Rolled Steel2.4/1.2-1.21/410"KeyedNoneA$ 910.12
C20VD13NEMA Premium(R)56CRolled Steel4.6/2.4-2.31/29.375"KeyedAutoA$ 937.98
B20VD11NEMA Premium(R)56Rolled Steel2.4/1.2-1.21/48.75"KeyedNoneA$ 764.11
B20VD10NEMA Premium(R)56Rolled Steel4.6/2.4-2.31/29.5"KeyedManualA$ 1071.06
B20VD08NEMA Premium(R)56Rolled Steel4.6/2.4-2.31/29.5"KeyedAutoA$ 882.93
DAYTON -

General Purpose Motor Cap Start/Run Open Drip-proof

Dayton general-purpose capacitor start motors provide additional power during the startup, ideal for use in air conditioners, auger drives, compressors, conveyors, fans and pumps. These single phase single speed motors are enclosed in a NEMA-rated frame for added safety and feature 2 capacitors for generating higher torque speeds of 1800 RPM. The motor provides continuous operation and are cradle base mounted on a horizontal surface, including ball bearings for smooth operation. Choose from a wide range of these capacitor start motors, available in 2 and 3/4 hp motor power ratings on Raptor Supplies.

StyleModelFrameFull Load AmpsHPInsulation ClassLength Less ShaftMotor Thermal ProtectionNameplate RPMNominal EfficiencyPrice (inc. GST)
A30PT73567.4/3.73/4B11.875"Auto114080.2%A$ 1586.15
B30PT72567.4/3.73/4B11.875"None114080.2%A$ 1595.62
C30PT8656H18.0/9.02F12.375"Auto172584.5%A$ 1661.97
D30PT8756H18.0/9.02F12.375"None172584.5%A$ 1557.78
DAYTON -

General Purpose Motors, 3 Phase

Dayton general purpose 3 phase AC motors are designed for continuous duty operations in pumps, fans, blowers and conveyors. These motors are single speed and are capable of producing a maximum speed of 3450RPM. Their rolled steel construction with open dripproof enclosure provide corrosion resistance and safe operation. They are Class B insulated for withstanding high temperatures. These motors can be mounted in both horizontal and vertical orientation. The NEMA rated nominal efficiency ensures maximum energy savings. Choose from a wide range of these general purpose motors, available in 1/4, 1/3 and 1/2 HP on Raptor Supplies.

StyleModelFull Load AmpsHPLength Less ShaftNameplate RPMNominal EfficiencyOverall LengthRPM GroupRPM RangePrice (inc. GST)
A20CL671.0-1.0/0.501/48.75"172569.5%10.375"1701-18001701-1800A$ 751.72
A20CL681.2-1.2/0.601/39.375"172573.4%10.875"1701-18001701-1800A$ 790.32
A20CL651.4-1.4/0.701/37.75"345069.5%9 5/16"3001-36003001-3600A$ 656.15
B20CL661.7-1.8/0.901/27 15/16"345073.4%9.437"3001-36003001-3600A$ 654.97
DAYTON -

General Purpose Motors, ODP Enclosure, 3/4 HP Power Output

Dayton general purpose motors are used with compressors, fans, conveyors, pumps, material handling and machine tools. These motors have steel construction with 3-phase motor design to operate with higher torque and greater efficiency, as compared to single-phase models having the same power outputs (hp), speeds (rpm) and frame sizes. They also feature open drip-proof (ODP) enclosures that have ventilated openings to allow inflow of external cooling air. These units are further integrated with ball bearings for smooth operation and can be mounted in horizontal position. Choose from a wide range of these general purpose AC motors, available in 56C and 56HC frame options.

StyleModelFrameFull Load AmpsLength Less ShaftNameplate RPMNominal EfficiencyOverall LengthRPM GroupRPM RangePrice (inc. GST)
A31LH4556C2.5-2.3/1.17.125"348576.8%10 11/16"3001-36003001-3600A$ 481.77
B31LH6356C2.5-2.3/1.28.5"176081.1%11.125"1701-18001701-1800A$ 510.71
C31LH4656C2.5-2.3/1.28.5"176081.1%11.125"1701-18001701-1800A$ 515.29
D31LH6256C2.5-2.3/1.16 29/32"348576.8%10 11/16"3001-36003001-3600A$ 486.01
E31LH4756HC2.9-2.6/1.38 29/32"115081.7%11.5"1101-12001101-1200A$ 461.00
F31LH6456HC2.9-2.6/1.38 15/16"115081.7%11.5"1101-12001101-1200A$ 461.00
12

Features

  • The brand's 3-phase AC motors have three windings to generate a magnetic field inside the frame of the motor and are ideal for use in non-hazardous applications. These 3-phase general-purpose motors feature NEMA frame construction with standard dimensions that permit drop-in replacement of motors.
  • Dayton DC component motors have ball bearings for efficient and low-friction support for smooth operation. They come with an insulation Class B certification to handle moderate temperatures. These motors feature a totally enclosed, non-ventilated (TENV) enclosure designed for protection in environments where ventilation is limited.

Working Mechanism

  • Electric power is supplied to the motor.
  • The motor's stator generates a rotating magnetic field.
  • This magnetic field induces a current in the rotor, creating a second magnetic field.
  • The interaction between the stator and rotor magnetic fields causes the rotor to turn.
  • Mechanical power is then transferred from the rotating rotor to the connected machinery or load.
  • The motor continues to operate as long as electrical power is supplied.

Frequently Asked Questions

How do I install these Dayton AC motors?

  • Choose a suitable location for motor installation.
  • Securely mount the motor using appropriate hardware.
  • Connect the motor to the power supply following the wiring diagram.
  • Ensure proper grounding according to electrical codes.
  • Check and align the motor with connected machinery.
  • Perform a test run to check for issues and monitor performance.

What factors should I consider while choosing AC motors?

  • Consider voltage, frequency and current for power requirements.
  • Match motor to application needs for speed and torque.
  • Choose single or three-phase based on the power supply for the motor type.
  • Ensure fit and suitable mounting for size and mounting.
  • Opt for high-efficiency motors for energy savings.
  • Account for operating conditions in the environment.
  • Evaluate requirements and use soft starters if needed for start/stop.
  • Assess ease of maintenance and parts availability.

We are here to help!

Looking for a part not listed here?