Hydronic Unit Heaters

Filter

Dayton hydronic unit heaters are designed for utilising non-potable hot water or steam produced by an indirect water heater or a boiler. These hydronic unit heaters are used in warehouses,... Read More

DAYTON -

Horizontal Hydronic Unit Heaters, Water Or Steam Heating

Dayton horizontal hydronic unit heaters mount on walls for heating large areas, commercial and industrial spaces. These heaters feature threaded female NPT connections for the supply of water or steam to heat the air and have fans to push & spread the heated air horizontally. They come with adjustable louvres for controlling the direction of airflow. Selected models allow vertical mounting on the ceiling to push the heated air downward towards the floor. Choose from a wide range of these heaters, available in airflow speeds ranging from 395 to 5500 cfm.

StyleModelAir FlowAmpsDepthHeightMax. Operating PsiMotor EnclosureMotor HpWidthPrice (inc. GST)
A5PV31395 cfm0.89"15"75Totally Enclosed16W14.5"A$ 1465.67
A3DUF7450 cfm0.89"18"150Totally Enclosed16W14.5"A$ 1828.52
A5PV43550 cfm1.29"18"75Totally Enclosed25W14.5"A$ 1921.08
A5PV46750 cfm1.411"20.25"75Totally Enclosed1/2017"A$ 2235.32
A5PV48900 cfm1.411"20.5"75Totally Enclosed1/2017"A$ 2550.55
A5PV47900 cfm1.411"20.5"75Totally Enclosed1/2017"A$ 2388.46
A5PV501100 cfm1.411"21.75"75Totally Enclosed1/2018.5"A$ 2684.90
A5PV491100 cfm1.411"21.75"75Totally Enclosed1/2018.5"A$ 2488.39
A5PV531400 cfm2.214"24"75Totally Enclosed1/1219.5"A$ 3272.54
A5PV521400 cfm2.214"24"75Totally Enclosed1/1219.5"A$ 3076.03
A5PV511400 cfm2.212"24.25"75Totally Enclosed1/1221"A$ 2809.12
A5YH201400 cfm2.212"24.25"75Totally Enclosed1/1221"A$ 2589.59
A5PV151800 cfm2.214"24"75Totally Enclosed1/1219.5"A$ 3168.86
A5PV161800 cfm2.214"24"75Totally Enclosed1/1219.5"A$ 3726.68
A5PV201900 cfm4.514"25.25"75Totally Enclosed1/321"A$ 3713.38
A5YH191900 cfm4.514"25.25"75Totally Enclosed1/321"A$ 3446.61
A5PV242000 cfm4.514"27.75"75Open Frame1/323.5"A$ 4095.52
A5PV232000 cfm4.514"27.75"75Open Frame1/323.5"A$ 3828.72
A5PV282200 cfm4.514"27.75"75Open Frame1/323.5"A$ 4337.66
A5PV322200 cfm4.514"29"75Open Frame1/324.5"A$ 4520.50
A5PV332200 cfm4.514"29"75Open Frame1/324.5"A$ 4787.30
A5PV272200 cfm4.514"27.75"75Open Frame1/323.5"A$ 3981.92
A5PV292600 cfm4.514"27.75"75Open Frame1/323.5"A$ 4239.96
A5PV302600 cfm4.514"27.75"75Open Frame1/323.5"A$ 4506.73
A5PV342900 cfm4.514"29"75Open Frame1/324.5"A$ 5016.25
DAYTON -

Suspended Vertical Hydronic Wall & Ceiling Unit Heaters

Dayton suspended vertical hydronic heater units provide primary or supplementary heating by pushing and spreading the heated air. They are suspended from a wall or ceiling to spread the air evenly. These units store water, which is then heated by passing a current through rectangular coils and circulated with a maximum rate of 75 PSI. They feature a totally enclosed motor capable of producing a maximum power output of 3 HP. The heater units are ETL & ETLc listed and complies with OSHA standards for safe use. Choose from a wide range of unit heaters, available in single and three phase variants on Raptor Supplies.

StyleModelAir FlowAmpsDepthHeightMotor HpPhaseVoltageWidthPrice (inc. GST)
A5PV6711,000 cfm9.842"24.25"33230/46042"A$ 15807.19
A5PV63595 cfm1.218.25"10.75"1/40111518.25"A$ 2146.98
A5PV66989 cfm2.121.25"11.125"1/20111521.25"A$ 2229.78
A5PV681200 cfm2.121.25"11.625"1/20111521.25"A$ 2746.42
A5PV541490 cfm1.225.25"12.13"1/8111525.25"A$ 2848.56
A5PV551790 cfm2.325.25"12.75"1/6111525.25"A$ 3174.26
A5PV562220 cfm2.329.5"13.625"1/6111529.5"A$ 3411.64
A5PV572620 cfm2.329.5"14.13"1/6111529.5"A$ 3566.89
A5PV594180 cfm3.637.5"5.125"1/4111537.5"A$ 6152.69
A5PV604430 cfm5.437.5"15.25"1/2111537.5"A$ 6418.54
A5PV615210 cfm3.237.5"16.75"3/43230/46037.5"A$ 6997.99
A5PV626140 cfm3.237.5"17.625"3/43230/46037.5"A$ 8065.20
A5PV648020 cfm5.0042"17.25"1.53230/46042"A$ 11423.61
A5PV659450 cfm5.0042"20.75"1.53230/46042"A$ 14078.26
DAYTON -

Suspended Horizontal Hydronic Wall & Ceiling Unit Heaters

Dayton suspended horizontal hydronic heaters provide primary or supplementary heating by pushing and spreading the heated air. They are suspended from a wall or ceiling to spread the air evenly. These units store water which is then heated by passing a current through serpentine coils and circulated with a maximum rate of 150 PSI. They feature a totally enclosed motor which is capable of producing a maximum power output of 25W. They are ETL & ETLc listed and comply with OSHA standards for safe use. Choose from a wide range of these heaters, available in 245, 500, 580 and 850 CFM airflow ratings on Raptor Supplies.

StyleModelAir FlowAmpsDepthHeightMotor HpWidthPrice (inc. GST)
A5YH18245 cfm0.83.75"16"16W18"A$ 1537.24
A5PV19500 cfm0.87.75"16"16W18"A$ 1655.61
A5PV22580 cfm1.28.75"16"25W18"A$ 1824.57
A5PV26850 cfm1.410.5"18.5"1/2020.5"A$ 2203.68

Hydronic Unit Heaters

Hydronic unit heaters utilize non-potable hot water or steam produced by a boiler, indirect water heater. Dayton heaters save floor space and are therefore commonly used in large areas like manufacturing facilities, warehouses and garages. These heaters are capable of pushing heated air horizontally and vertically and spread it across a larger area. Choose from a broad range of these Dayton hydronic heating units, available in 11000 cfm, 500 cfm, 450 cfm, 395 cfm and 245 cfm air flow options.

Working Mechanism

  • Hot water is produced by a central boiler for heating the water to the required temperature.
  • The hot water is then circulated through a series of heating coils / radiators within the unit heater.
  • The heat from the hot water is then transferred to the surrounding air through the heating coils.
  • A fan or blower inside the unit heater circulates the warm air into the heated space.
  • The cooled water then returns to the central boiler for reheating and the cycle repeats.
  • The temperature of the hot water is then controlled by adjusting the temperature setting on the central boiler and the amount of heat produced by the unit heater can be adjusted by controlling the flow of hot water through the heating coils or radiators.

Features

  • Dayton water & steam heated horizontal hydronic unit heaters come with fans to spread & push the heated air horizontally. These heaters have threaded female NPT connections to supply water / steam for heating the air and are equipped with adjustable louvres to control the direction of airflow. They can be mounted on walls for heating industrial spaces.
  • Dayton suspended vertical hydronic heaters are mounted on the ceiling or wall vertically to spread the air evenly. They feature a totally enclosed motor for protection from dust and have a maximum operating pressure of 75 PSI. These heater units are ETL & ETLc listed and comply with OSHA standards for safe & secure operations.
  • Dayton water heated horizontal hydronic unit heaters are suspended from a wall / ceiling horizontally to spread the air evenly. These units heat the stored water by passing a current through serpentine coils.

Frequently Asked Questions

What is the flow rate of Dayton hydronic unit heaters?

The flow rate of these heaters range from 245 to 11000 cfm.

What safety precautions should be taken when using hydronic unit heaters?

  • Get the system installed by a qualified technician.
  • Inspect the central boiler regularly and maintain it to ensure safe operation.

What is the role of a thermostat in hydronic unit heaters?

The thermostat controls the temperature of the hot water and the rate of heat transfer. The thermostat is set to the desired temperature and will turn the unit on and off as needed to maintain the required temperature.

We are here to help!

Looking for a part not listed here?