YELLOW JACKET Manifold Gauge Set Accessories

Includes hoses, adapters, gauges & couplers available in different angles, colours, connection sizes and materials for upgrading / replacing the existing components of manifold gauge sets

Filter

YELLOW JACKET manifold gauge set accessories are the additional components or attachments used with a manifold gauge set. These accessories serve various purposes, such as enhancing functionality,... Read More

YELLOW JACKET -

Heat Pump Manifold Accessories

StyleModelColorTypePrice (inc. GST)
A49134BlueLow SideA$ 85.42
B49133RedHigh SideA$ 84.23
YELLOW JACKET -

HVAC Quick Couplers

StyleModelAngleConnection SizeTypePrice (inc. GST)
A191090 Degrees1/4"StraightA$ 46.28
B1920845 Degrees1/4" Female x 1/4" MaleH VACA$ 54.13
C1920990 Degrees1/4"90 DegreesA$ 47.32
YELLOW JACKET -

Plus II Charging Hose Sets

StyleModelLengthPrice (inc. GST)
A2198448"A$ 192.09
B2998448"A$ 375.58
A2198672"A$ 232.91
B2998672"A$ 399.83
YELLOW JACKET -

Plus II Charging Hoses

StyleModelAngleBurst PressureColorConnection SizeLengthNumber Of HosesTypeWorking PressurePrice (inc. GST)
A290600 Degrees4000 PSIYellow1/4" Female60"1Refrigeration and Air Conditioning800 PSIA$ 119.88
B296600 Degrees4000 PSIRed1/4" Female60"1Refrigeration and Air Conditioning800 PSIA$ 118.04
C299850 Degrees4000 PSIYellow/Blue/Red1/4" Female60"3Refrigeration and Air Conditioning800 PSIA$ 345.94
D210600 Degrees4000 PSIYellow1/4" Straight60"1Refrigeration and Air Conditioning800 PSIA$ 69.17
B216600 Degrees4000 PSIRed1/4" Straight60"1Refrigeration and Air Conditioning800 PSIA$ 69.17
E212600 Degrees4000 PSIBlue1/4" Straight60"1Refrigeration and Air Conditioning800 PSIA$ 69.17
A145600 Degrees3000 psiYellow3/8" Straight60"1Refrigeration and Air Conditioning600 PSIA$ 116.96
F219850 Degrees4000 PSIRed, Yellow, Blue Set1/4" Straight60"3Refrigeration and Air Conditioning800 PSIA$ 199.44
E292600 Degrees4000 PSIBlue1/4" Female60"1Refrigeration and Air Conditioning800 PSIA$ 118.04
G2298445 Degrees4000 PSIYellow/Blue/Red1/4"48"3Refrigeration and Air Conditioning800 PSIA$ 257.70
H2598645 Degrees4000 PSIRed, Yellow, Blue1/4" Female72"3H VAC800 PSIA$ 441.37
I2598545 Degrees4000 PSIRed, Yellow, Blue1/4" Female60"3H VAC800 PSIA$ 397.78
J2298345 Degrees4000 PSIRed, Yellow, Blue1/4" Female36"3H VAC800 PSIA$ 224.69
K2198345 Degrees4000 PSIRed, Yellow, Blue1/4" Female36"3H VAC800 PSIA$ 171.78
L2298645 Degrees4000 PSIYellow/Blue/Red1/4"72"3Refrigeration and Air Conditioning800 PSIA$ 296.01
M2124845 Degrees4000 PSIBlue1/4"48"1Refrigeration and Air Conditioning800 PSIA$ 65.34
M2167245 Degrees4000 PSIRed1/4"72"1Refrigeration and Air Conditioning800 PSIA$ 78.48
RFQ
M2127245 Degrees4000 PSIBlue1/4"72"1Refrigeration and Air Conditioning800 PSIA$ 78.48
M2107245 Degrees4000 PSIYellow1/4"72"1Refrigeration and Air Conditioning800 PSIA$ 78.48
RFQ
M2164845 Degrees4000 PSIRed1/4"48"1Refrigeration and Air Conditioning800 PSIA$ 65.39
M2104845 Degrees4000 PSIYellow1/4"48"1Refrigeration and Air Conditioning800 PSIA$ 65.41
N2298545 Degrees4000 PSIRed, Yellow, Blue Set1/4" Female60"3Refrigeration and Air Conditioning800 PSIA$ 279.28
O2998345 Degrees4000 PSIRed, Yellow, Blue1/4" Female36"3H VAC800 PSIA$ 326.58
YELLOW JACKET -

Charging Hoses

Yellow Jacket charging hoses are used to service the refrigerant content in ammonia lines, cylinder valves and fuel oil assemblies. These hoses are designed with a moisture barrier to provide enhanced resistance to moisture migration, which, as a result may contaminate expensive refrigerants. The nylon permeation barrier of these Yellow Jacket hoses adheres to SAE requirements J2196 for CFC, HCFC and HFC refrigerants. A wide range of these hoses are available in red, blue and yellow colour options on raptor Supplies.

StyleModelColorConnection SizeItemLengthNumber Of HosesTypePrice (inc. GST)
A25202Blue1/4" FemaleCharging Hose9"1H VACA$ 91.81
B25602Red1/4" FemaleCharging Hose9"1H VACA$ 90.39
C25980Red, Yellow, Blue1/4" FemaleCharging Hose Set9"3H VACA$ 271.80
D21990Red, Yellow, Blue, Black1/4"Charging Hose60"4Refrigeration and Air ConditioningA$ 299.47
E25002Yellow1/4" FemaleCharging Hose9"1H VACA$ 88.27
YELLOW JACKET -

Liquid Charging Adapter, 1/4 Inch Female x 1/4 Inch Male

ModelItemPrice (inc. GST)
41123AB8TLJA$ 35.14

Features

  • They feature burst pressure options of 3000 psi and 4000 psi for durability and reliability.
  • They are available in lengths ranging from 9 to 72 inches, catering to various system configurations.
  • They have working pressure ranging from 0 to 800 PSI, ensuring adaptability to diverse applications.
  • YELLOW JACKET heat pump manifold accessories have a connection size of 1/8 inch MPT, ensuring compatibility with various equipment setups. These gauge sets offer a non-liquid-filled gauge type, reducing the risk of leaks and ensuring long-term reliability.

Frequently Asked Questions

What safety precautions should I follow when using these accessories?

  • Wear appropriate personal protective equipment (PPE), including gloves and safety glasses.
  • Familiarise yourself with the specific safety guidelines in the user manual.
  • Ensure the HVAC system is properly shut off and depressurised before connecting accessories.
  • Use caution when handling pressurised components to avoid injury.
  • Regularly inspect accessories for signs of wear, damage or leaks.
  • Avoid overpressurising the system beyond the recommended working pressure range.
  • Keep the work area well-ventilated to minimise exposure to hazardous substances.
  • Follow proper storage and handling procedures for refrigerants and chemicals.
  • Consult with a qualified HVAC technician if unsure about safety procedures.

What are the factors to consider while choosing these manifold gauge set accessories?

Major factors include compatibility, functionality, quality, versatility, accuracy, safety features and ease of use.

How do I properly purge air from my manifold after replacing hoses or accessories?

  • Ensure the manifold valves are closed and the manifold is connected to the system.
  • Open the low-pressure valve on the manifold gauge set.
  • Slowly open the high-pressure valve to allow refrigerant to flow into the manifold and purge any air trapped in the hoses.
  • Close the high-pressure valve once refrigerant starts flowing steadily from the manifold.
  • Open the high-pressure valve on the manifold gauge set.
  • Slowly open the low-pressure valve to allow refrigerant to flow through the low side of the system and purge any remaining air.
  • Close the low-pressure valve once refrigerant flows steadily from the manifold.
  • Verify that all connections are secure and there are no leaks.
  • Follow proper safety precautions and regulations when working with refrigerants.

We are here to help!

Looking for a part not listed here?